Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 38(1): 86-92, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891142

RESUMO

OBJECTIVES: To study the quantitative potency of plasma albumin on cardioprotection in terms of creatinine kinase-myocardial band mass (CK-MBm) in on-pump cardiac surgery. DESIGN: Post hoc analysis of a double-blinded randomized clinical trial. SETTING: Single-center study in the Helsinki University Hospital. PARTICIPANTS: A total of 1,386 adult on-pump cardiac surgical patients. INTERVENTION: Administration of 4% albumin (n = 693) or Ringers acetate (n = 693) for cardiopulmonary bypass priming and volume replacement intraoperatively and postoperatively during the first 24 hours. MEASUREMENTS AND MAIN RESULTS: Albumin concentration was measured preoperatively and intraoperatively (after protamine administration), and CK-MBm on the first postoperative morning. Multivariate linear regression analyses were measured in the whole cohort and the Ringer group. Plasma albumin concentration did not differ between the groups preoperatively (Ringer v albumin: 38.3 ± 5.0 g/L v 38.6 ± 4.5 g/L; p = 0.171) but differed intraoperatively (29.5 ± 5.2 g/L v 41.5 ± 6.0 g/L; p < 0.001). Creatinine kinase-myocardial band mass was higher in the Ringer (32.0 ± 34.8 µg/L) than in the albumin group (24.3 ± 33.0 µg/L) (p < 0.001). Aortic cross-clamping time associated with CK-MBm in the whole cohort (standardized ß = 0.376 [95% CI 0.315-0.437], p < 0.001) and the Ringer group (ß = 0.363 [0.273-0.452]; p < 0.001). Albumin administration in the whole cohort (ß = -0.156 [-0.201 to -0.111]; p < 0.001) and high intraoperative albumin concentration in the Ringer group (ß = -0.07 [-0.140 to -0.003]; p = 0.04) associated with reduced CK-MBm. Compared with ischemia-induced increase in CK-MBm, albumin's potency to reduce CK-MBm was 41% in the whole cohort (ß-value ratio of -0.156/0.376) and 19% in the Ringer group (ß-value ratio of -0.07/0.363). CONCLUSION: Both endogenous and exogenous albumin appear to be cardioprotective regarding CK-MBm release in on-pump cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Creatinina , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Albumina Sérica
2.
Ann Thorac Surg ; 116(2): 392-399, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37120084

RESUMO

BACKGROUND: In the recent ALBICS (ALBumin In Cardiac Surgery) trial, 4% albumin used for cardiopulmonary bypass priming and volume replacement increased perioperative bleeding compared with Ringer acetate. In the present exploratory study, albumin-related bleeding was further characterized. METHODS: Ringer acetate and 4% albumin were compared in a randomized, double-blinded fashion in 1386 on-pump adult cardiac surgery patients. The study end points for bleeding were the Universal Definition of Perioperative Bleeding (UDPB) class and its components. RESULTS: The UDPB bleeding grades were higher in the albumin group than the Ringer group: "insignificant" (albumin vs Ringer: 47.5% vs 62.9%), "mild" (12.7% vs 8.9%), "moderate" (28.7% vs 24.4%), "severe" (10.2% vs 3.2%), and "massive" (0.9% vs. 0.6%; P < .001). Patients in the albumin group received red blood cells (45.2% vs 31.5%; odds ratio [OR], 1.80; 95% CI, 1.44-2.24; P < .001), platelets (33.3% vs 21.8%; OR, 1.79; 95% CI, 1.41-2.28; P < .001), and fibrinogen (5.6% vs 2.6%; OR, 2.24; 95% CI, 1.27-3.95; P < .05), and underwent resternotomy (5.3% vs 1.9%; OR, 2.95; 95% CI, 1.55-5.60, P < .001) more often than patients in the Ringer group. The strongest predictors of bleeding were albumin group allocation (OR, 2.18; 95% CI, 1.74-2.74) and complex (OR, 2.61; 95% CI, 2.02-3.37) and urgent surgery (OR, 1.63; 95% CI, 1.26-2.13). In interaction analysis, the effect of albumin on the risk of bleeding was stronger in patients on preoperative acetylsalicylic acid. CONCLUSIONS: Perioperative administration of albumin, compared with Ringer's acetate, resulted in increased blood loss and higher UDBP class. The magnitude of this effect was similar to the complexity and urgency of the surgery.


Assuntos
Albuminas , Perda Sanguínea Cirúrgica , Procedimentos Cirúrgicos Cardíacos , Solução de Ringer , Humanos , Albuminas/administração & dosagem , Albuminas/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/normas , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/normas , Solução de Ringer/administração & dosagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento